3. At this point, press the <Enter> key. (It may take a few seconds to complete booting).
Power should be cycled to the device while connected to it in order to see the “Load Completed...”
message.
If it appears that nothing changes after pressing the <Enter> key, it is possible that the Lantronix
MSS1 or MSS100 device was already configured once. If this occurs, you need to press the
<Enter> key before the phrase, “Load Completed-Boot in Progress” appears. If this still does not
allow you to enter into the command mode, you may also telnet into the Lantronix device.
If the device was configured previously, it may be best to do a hard reset and configure it from
scratch. To do this:
a. Using the end of a paper clip, or a similar small object, hold down the reset button.
b. Cycle power to the device.
A prompt that says Local_1> should appear. If the prompt says Boot>, then the Ethernet
Address has not been defined and you must enter one.
a. At the Boot> prompt, type change hardware n, where n represents the last three
digits of the Ethernet Address located on the bottom of the Lantronix box (Example: change
hardware 21-01-65).
b. Reboot for the change to take effect.
c. Wait for it to finish loading. Once it’s done, you should see a screen resembling the picture on
the previous page.
4. You will be prompted for a user name. Enter any name.