User manual
Receivers
28 —
revision 3
5.1.2 D6600 Receiver Output Modes
In order to configure the different output modes for the receiver, enter into the Automation Configuration
menu on the receiver. In order to do this you need to do the following:
1. Press the [M/E] button on the front of the receiver.
2. You will be prompted for a password. Enter the password configured for the receiver and press [M/E]
again.
3. A message will appear indicating that you are logged in. Use the up and down arrows to navigate to
different sections.
4. Using the down arrow, go to CPU Configuration. Press [M/E] again.
5. Once again use the down arrow to go to the Automation Configuration item and press [M/E].
6. In the menu, go to the entry labeled Output Format. One or two formats will be listed, depending on
the current format: one for the 6500 output mode and one for the SIA format.
• To change this setting, press the [M/E] button, then press either one or two for the output desired.
Then press [M/E] again.
7. Log out of the system. To do this, press the [CAN] button until the standard screen with date and time is
displayed.
When in the Automation Configuration section of the receiver settings in this screen, you can modify the
Heartbeat Interval, Start Character (HEX) and End Character (HEX) as well as communication settings
(such as baud rate, byte size, parity, and stop bits). These items are listed in the receiver menu under
Automation Configuration as follows:
5.1.3 Configuring Receiver Communications
The Radionics receiver can be connected to a host computer and can communicate through B.A.S.I.S. in one
of two ways:
• Direct connection of the host machine and the receiver using a NULL modem cable
• Connection of the receiver through a Lantronix box
If a LAN connection will be used, configuration of the communication settings in the Lantronix box will
differ from configuration for use with BEST hardware.
Baud Rate Default value = 4 Corresponds to baud rate of 1200
Data Bit Default value = 8 Corresponds to byte size of 8
Parity Default value = 0 Corresponds to parity of NONE
Stop Bit Default value = 1 Corresponds to 1 stop bit
Link Test Default value = 5 Corresponds to heartbeat interval of 5 seconds
Header Default value = 1 Corresponds to start character of 1
Trailer Default value = D Corresponds to end character of D