User manual
OEM Device Configuration Guide
revision 3 — 23
h. Set the flush mode to 00.
i. Set the disconnect time (DisConnTime) to 00:00.
j. For SendChar 1 and SendChar 2, the values can be set to 00.
6. Select 5 for Expert Settings.
It is recommended that you set the TCP Keepalive time to 15 seconds. It is set to 0 by default. This
option specified the amount of time (during a silent connection) before attempting to check if the
network device is still online. If there is no response within this time period, the connection is dropped.
7. Select 9 to save and exit.
3.3. Downstream Devices
For any additional downstream devices supported, refer to the product user guide for wiring and
configuration.
Disable with hard disconnect 1
State LED off with connection (When there is a network
connection to or from the serial port, the state LED will turn
off instead of blink.)
1
Disconnect with EOT (^D) (When <Ctrl> + <D> or Hex 04
are detected, the connection is dropped. Both Telnet mode
and Disconnect with EOT must be enabled for Disconnect
with EOT to function properly. <Ctrl> + <D> will only be
detected going from the serial port to the network.)
1
Disconnect mode option 7 6 5 4 3 2 1 0