User manual

Intrusion Detection
18 —
revision 3
RS-232 Interface Control and Configuration
If you are using DS7400Xi version 3
1. Enter programmers’ mode. The default programmers code is 9876. Enter this code followed by [#], [0].
2. Enter the program address 0206.
3. For data digit 1, enter [1].
4. For data digit 2, enter [0] followed by [#].
5. Enter the program address 0207.
6. For data digit 1, enter [2] for 2400 baud or [4] for 9600 baud.
7. For data digit 2, enter [5] followed by [#].
8. To exit programmers’ mode, press and hold the [*] key for a few seconds.
Notes: For the DS7400Xi (version 3), the minimum firmware version is 3.09.
For the DS7400Xi (version 4+), the minimum firmware is version 4.03.
If you are using DS7400Xi version 4+
1. Enter programmers’ mode. The default programmers code is 9876. Enter this code followed by [#], [0].
2. Enter the program address 4019.
3. For data digit 1, enter [1].
4. For data digit 2, enter [0] followed by [#].
5. Enter the program address 4020.
6. For data digit 1, enter [2] for 2400 baud or [4] for 9600 baud.
7. For data digit 2, enter [5] followed by [#].
8. To exit programmers’ mode, press and hold the [*] key for a few seconds.
Note: For the DS7400Xi (version 4+), the minimum firmware version is 4.03.
Whenever the Detection Systems (version 3 or 4+) intrusion detection panel is online with the
communication server and configured to report alarms to a central station, communication to the DS7412
serial interface device will cease until the dialing and event reporting to the central station has completed.
This only happens in the case of alarm or panic report events sent to the central station. In addition, for any
other events configured to report to a central station, such as open/close, when the panel is online with the
communication server via the serial interface, these events will not cause the connection to drop. However,
these events will not be reported to the central station immediately either. These events will only be reported
to the central station once the communication session (with the communication server) has ended.
3.2. Radionics
To install the Radionics control/communicator panel and its components, refer to the product user guide.