Wiring the DS7412
4. Re-apply power and set the panel time and date using a master PIN.
Jumpers
There are three jumpers on the Detection Systems circuit board that must be configured.
Diagnostic LEDs
Jumper P2 controls the diagnostic LEDs, which can be used as a troubleshooting aid. To enable the LEDs,
place P2 on both pins.
The DS7412 draws more current in this mode so P2 should not be in place under normal circumstances.
RS-232 Cable Ground
Some printers may cause a ground fault condition on the control panel. If this occurs, remove P3. This will
disconnect the printer cable ground from the cabinet ground.
Some desktop computers can cause a ground fault even if P3 is removed. If connecting the DS7412 to a
desktop PC and a ground fault occurs, use the connection only temporarily and disconnect for normal
control operation.
OPT Tx Option bus transmit date to control panel
OPT Rx Option bus receive data from control panel
SER Rx RS-232 receive data from printer
SER Tx RS-232 transmit data to printer
RED
BLK
GRN
YEL
R
B
G
Y
DS7400Xi
Options Bus
1000 feet max.
P3
P2P4
RS-232 Serial Cable
50 feet max.
OPT
Tx Rx
Tx Rx
SER