User manual

OEM Device Configuration Guide
revision 3 — 13
2. Intercom Exchanges
For more detailed information, refer to the Zenitel user manual.
2.1. Zenitel AlphaCom
A standard RS-232 cable is used to communicate between the host computer and the Zenitel (formerly
known as Stentofon) AlphaCom unit. Connect the RS-232 cable to the data port on the back of the
AlphaCom unit.
The integration requires that the AlphaCom exchanges have at least 7.10 firmware. Bi-directional
communication to the unit is used and this is only available in 7.10; earlier versions do not support this.
2.1.1 AlphaNet
Multiple exchanges can be connected together in a system referred to as AlphaNet. In order to place calls
from Alarm Monitoring, the following setting is required in the ACS.INI file:
[Stentofon]
AlphaNet=1