Specifications

C•CURE apC/L Technical Manual
Setting Up the apC/L Panel
6-5
Table 6.1 apC/L DIP Switch Settings
Switch/Jumper Setting Default=* System Feature
SW3:1 ON Database cleared on power up and/or
reset
OFF * Database not cleared on power up and/
or reset
SW3:2 ON Dialup mode communication is enabled
OFF * Dialup mode communication is disabled
SW3:3 ON CTS is enabled (for 5-wire RS 232
applications)
OFF * CTS is disabled
SW3:4 ON Host parity none, 8 data bits, 1 stop bit
OFF * Host parity even, 8 data bits, 1 stop bit
SW3:5-7 Host baud rate (see separate table later
in this chapter)
SW3:8 ON apC/L unit number 17 -32 etc. in use
OFF apC/L unit number 1 through 16 in use
Note Switch setting OFF is the factory default. If set to off, the switch is
open. Switch setting ON means the switch is closed.