Specifications

C•CURE apC/L Technical Manual
R8 Output Module
5-5
R8 Output Module
The apC/L R8 Output Module (also referred to as the RM Output
Module), provides eight outputs. You can install a total of four Output
Modules on one apC/L. Like the Input Module, Output Modules connect
directly to the RS-485 line for the reader, which reduces wiring.
Figure 5.3 shows the layout of an Output Module.
Figure 5.3 apC/L Output Module
If the unit is “last in line,” put in jumper W1. If the unit is not “last in
line,” put in jumper W1 or one or the pins.
CAUTION
Maximum relay contact voltage on the output
module is 30V - AC or DC.
Output
connector
SW1 Address
switch
Port
connector
SW1
P1
P2
P3
P4
P9
1234
W1
NO
NC
C
P8
P7
P6
P5
NO
NC
C
NO
NC
C
NO
NC
C
NO
NC
C
Relay
3.93"
(9.98 cm)
1/8" hole
(3.2 mm)
5.31"
(13.45 cm)
NO
NC
C
NO
NC
C
NO
NC
C
W1
Tamper
Input
apcl.bk Page 5 Monday, May 15, 2000 3:21 PM