Specifications

C•CURE apC/L Technical Manual
Wiring Card Readers
4-26
To install the RM-4 module in the junction box:
1. Insert metal standoffs (not supplied) in the modules screw holes and
mount the module to the box.
2. Use 3/16” diameter round M/F 4-40 standoffs, with lengths
appropriate to your installation. For example, Globe part #A-6701-
440 is an acceptable 1/4” standoff.
Installing the RM1 or RM2 Reader Assembly
To install reader assembly:
1. Secure the reader backplate and gasket to the junction box with the
four mounting screws.
When RM or MRM readers are installed outdoors, the foam gasket
forms a weather seal.
2. Align all holes in the gasket with the holes in the backplate. Leave an
equal amount of gasket overlap on all sides of the plate.
If the reader is located in a high-static area or if it is not connected to
a grounded circuit, run a ground strap from the reader backplate to a
local AC ground or cold water pipe. Use as short a wire as possible.
Note Ensure that the mounting hole nearest the grounding lug (J5) of
the RM-4 is grounded to a proper earth ground or ground
directly to lug J5. See Figure 4.11.
CAUTION
Do not apply power to any equipment while it is
being installed. Apply power only after all procedures
in this chapter are completed, and the system is ready
for testing. Failure to follow this warning could result
in damage to equipment, personal injury, or death.
apcl.bk Page 26 Monday, May 15, 2000 3:21 PM