Specifications

C•CURE apC/L Technical Manual
Connecting the apC/L to the Host
2-13
To increase the distance between the host and the apC/L, you can use
modems, line drivers, or other communications devices. The next two
sections describe RS-232C and RS-485 connections.
RS-232C For RS-232C transmission, follow these steps:
1. Use twisted, shielded 22 AWG (0.325 mm) Belden #9855.
2. Connect the cable shield to the apC/L chassis ground.
The apC/L can be no further than 50 ft. (15 m) from the host, unless
you extend this distance with a modem, line driver, or other
communications device. Connect the apC/L directly to the host as
shown in Table 2.6.
Note You must configure jumpers W9-W14 on the apC/L for the
communications protocol being used. For host communication
using the RS-232C communication protocol, set jumpers W9-
W14 to the B position. See “Setting apC/L Jumpers” on page 6-7
for further information on jumper settings.
Note Connect the apC/L chassis to a proper ground only at one end.
Table 2.6 apC/L Connection to Host PC
apC/L Host
apC/L Pin apC/L Signal DB-25
Pin
DB-9
Pin
Host Signal
P10-1 Data transmit (TX) 3 2 Data receive (RX)
P10-4 Data receive (RX) 2 3 Data transmit (TX)
P10-5 Ground (GND) 7 5 Ground (GND)
27C1024