Specifications

C•CURE apC/L Technical Manual
Using the Worksheet
B-4
5. In each of the boxes in the wire length column below the box used in step
4, enter the wire lengths between the readers in the chain. Use only the
rows corresponding to your number of readers. You will not use all rows
unless you have two readers and four input and four output modules.
6. Multiply the figures across in each row. Enter the result in each box of the
Total power drop column.
7. Add the Total voltage drop column. The total cannot exceed 4.5 volts. If
your total is greater than 4.5 volts, you must do one of the following to
ensure proper operation of the RM module:
Shorten the wire lengths
Use a heavier wire
Use a local power supply