If the answer (and/or originate) connect baud rate is to be other than the DTE rate or if a
particular answer (and/or originate) connect baud rate is desired it must be configured through
the answer (and/or originate) modem string.
The RSX will not adjust its DTE rate to that of
the negotiated connection baud rate. This is not a problem for those modems which fix
the DTE rate regardless of the connection rate (DCE rate). For modems that adjust the
DTE rate to the connection rate, the connection rate should be fixed to the DTE rate
through the use of appropriate Call Answering and Call Origination setup strings. See
Table 6 for recommendations.
Typical External Modem Setup Strings
The following table will help configure the most popular external modems for use with the RSX.
In general, modems should be set for error correction disabled, flow control disabled, and data
compression disabled.
No Flow
Control
Data
Compression
Off
No error
control
Fixed Serial
Port Rate
Setting the
connect rate for
fixed 9600
See external
modem mfr. manual
for other connect
baud rates.
USRobotics
&H0 &K0 &M0 &B1 &N6
Motorola
&K0 \Q0 %C0 \N1
1
Not
available
N0 S37=9
Hayes
&K0 &Q0
2
Not
available
N0 S37=9
Other (Boca,
Zoom,
Cardinal)
&K0 %C0 \N1
1
Not
available
+MS=9,0,9600,9600
Table 6 : External Modem Setup Strings