Specifications

Starting
Engines 23hp 45hp with Restrictor Plug
*All safety switches must be in place and in working order according to OEM specifications*
Cold Start:
1. Turn on tank
2. Turn fuel control valve 1 turn
3. Push primer button for 2 counts to purge line of air and fill with fuel
4. Set throttle at highest position
5. Start engine. If the engine will not start, please repeat the installation instruction that applies to
your application. Do not over-prime the regulator if it is over-primed because the lever within the
regulator will break and ruin the regulator. This is not covered under warranty.
6. When engine starts, turn adjustment dial for final adjustment, typically 2 turns open.
7. If the engine will not start, please repeat the installation that applies to your application.
Do not over-prime. Stop priming when resistance is felt on the primer. Forcing the primer
will damage the regulator and is not covered under warranty.
Warm Start:
1. Set throttle at highest position
2. Turn key to start position and run as normal
Stopping
All Engines
1. Slow engine down to near idle
2. Turn engine off
3. If unit is to be stored or transported in an enclosed area or trailer, close valve on propane
cylinder(s).
4. Close valve on propane cylinders on any unit that will not be restarted within a few minutes.
5. The Fuel Control Valve on the Regulation System does not need to be closed as long as the valve on
the attached propane cylinder is closed.
6. If the engine will not start, please repeat the installation instruction that applies to your application.
Do not over-prime the regulator if it is over-primed because the lever within the regulator will break
and ruin the regulator. This is not covered under warranty.