Cycle Life Improvements with ACT Charging
The following graphs show the cycle life gains for the 3 main battery chemistries in use in the two-way radio
industry. These cycle life tests were performed by the US military in the late 1990’s when evaluating ACT’s
patented adaptive charging. Operational use has shown a minimum gain of 2-3 times the charge cycle life
compared to standard rapid charging techniques.
ACT NiCd Battery Test ReportACT -
50
60
70
80
90
100
110
0
100
300
500
700
900
1100
1300
1500
1700
1900
2100
2300
2500
Number of Charge / Discharge Cycles
% of Capacity
Design Life
Field Experience
Using ACT
NiCd Batteries
ACT NiMhd Battery Test Report
1Hr Charge/ IC Discharge to 1V per Cell
60
70
80
90
100
110
0 100 300 500 700 900 1100 1200 1300 1400
Number of Charge / Discharge Cycles
% of Capacity
Other Chargers
ACT
NiMH Batteries
ACT Lion Battery Test Report
1Hr Charge/ IC Discharge to 100%
60
70
80
90
100
110
0 100 300 500 700 900 1100 1300 1500 1700 1814
Number of Charge / Discharge Cycles
% of Capacity
Using ACT
Other Chargers
LiIon Batteries