Specifications

T1 CSU/DSU
16
3. CHANNEL SEND TIMING:
A. LOOP 1 (Terminal Timing) ........................................S1-5: ON
B. LOOP 2 (Send Timing) ...............................................S1-5: OFF
4. CHANNEL TIMING:
A. NORMAL.......................................................................S1-6: ON
B. INVERTED ....................................................................S1-6: OFF
5. CHANNEL DATA:
A. NORMAL ......................................................................S1-7: 0N
B. INVERTED ....................................................................S1-7: OFF
6. REQUEST TO SEND CONTROL
A. ALWAYS ON ..................................................................S1-8: ON
B. CONTROLLED .............................................................S1-8: OFF
7. AGGREGATE TIMING SELECTION:
A. INTERNAL (MASTER) CRYSTAL TIMING........................S1-9: ON
S1-1 0: ON
B. LOOP (SLAVE) TIMING......................................................S1-9: OFF
S1-1 0: ON
C. EXTERNAL CHANNEL TIMING (NOTE 1 ).....................S1-9: ON
S1-1 0: OFF
D. INTERNAL (MASTER) CRYSTAL TIMING .......................S1-9: OFF
S1-10: OFF
NOTE
If the EXTERNAL CHANNEL TIMING
selection is made, then the associated
CHANNEL SEND TIMING must be set to Loop
1 Timing. When operating in this mode, the
DCE provides the network timing.