Specifications

72
CSU/DSU MS DBU
12. Testing and Troubleshooting
12.1 Test Overview
The CSU/DSU MS DBU performs a variety of diagnostic functions that isolate
portions of the circuit to identify the source of the problem. Tests may be initiated
and terminated through the front panel, VT100 terminal, SNMP, or TELNET.
In asynchronous mode, AT commands can control the testing from the DTE
interface. For synchronous operation, V.25 bis commands can provide test control.
The unit also responds to standard DDS network tests initiated from telco test
centers. In addition, it can run several tests such as local and remote loopbacks
to aid in problem isolation. See Figure 12-1.
Figure 12-1. Normal Operation Before Initiating Loopback Test.
CAUTION
All diagnostic tests disrupt data flow.
12.1.1 I
NITIATING A
T
EST
Initiate tests using the following procedure:
1. Select Test from the Main menu by pressing 2, then press Enter.
2. Specify local, remote, or DBU testing by selecting the corresponding number,
followed by Enter.
3. Use the Up and Down arrows to view test options.
LOCAL
DSU/CSU
REMOTE
DSU/CSU
DTE DTE
RD
TD
TELCO
Rx
Tx
Rx
Tx
RD
TD
Rx
Tx
Rx
Tx