Specifications
69
CHAPTER 11: Configuring Unit Utilities
11.1 Manual Command
The Manual Command option is a shortcut method for entering configuration
and control commands for the CSU/DSU MS DBU. Figure 11-1 shows the menu
path for the manual command. The available manual commands are listed in
Table 11-1. When using the front panel, perform the following steps to enter
a manual command:
1. Select 3 = CONFIG from the Main menu.
2. Select 1 = LOCAL.
3. Select 6 = UTILITIES.
4. Select 1 = MANUAL COMMAND.
5. The first display prompts you for command-number entry:
COMMAND:00
Use the Up-Arrow key to delete the current entry, then use the number keys to
enter the new value. Press Shift to activate letters A–F.
6. Press Enter to complete the Command entry.
7. Once the command number is entered, the display shows both the command
number and the present value or setting for the command. The command
value can be edited or reissued with the existing value:
COMMAND: XX
VALUE: 00
8. Use the number keys to enter the hexadecimal value. Press Enter to complete.
The system briefly displays Command Accepted (if the entry is valid) and
returns to the active menu.