Specifications

47
CHAPTER 7: Configuring DTE Options
Table 7-1 (continued). DTE Options AT Commands
Front Panel AT Description
Command
CS Options (continued)
5=OFF WITH LOCD &R4 Off 5 sec after LOCD (SW56 only)
For Follows RS options, select the length of the delay.
1=CS DELAY SHORT _D0 Short delay from RS to CS selected
2=CS DELAY LONG _D1 Long delay from RS to CS selected
Anti-Stream
1=TIMER OFF %T0 Anti-stream timer disabled
2=TIME 10 SEC. %T1 Timeout equals 10 seconds
3=TIME 30 SEC. %T2 Timeout equals 30 seconds
4=TIME 60 SEC. %T3 Timeout equals 60 seconds
CD Options
1=FORCED ON &C0 On all the time
2=NORMAL &C1 On only when data present on loop
3=OFF WITH LOCD &C2 On except after disconnect (SW56 only)
TR Options
1=IGNORED &D0 Ignore the TR input
2=IDLE WHEN OFF &D2 See the note on the next page.
3=OFF>ON DIAL #1 &D3 Dial Stored #1: TR goes off to on (SW56
only)
4=OFF >ON DIAL #2 &D4 Dial Stored #2: TR goes off to on (SW56
only)
5=NO DBU IF OFF &D3 No dial backup if TR is off.
(valid only when DBU
module is installed and
Network Type is set to
DEDICATED)
SR Options
1=FORCED ON &S0_C1 Always on
2=OFF OOS ONLY &S1_C1 Off when network out of service
3=OFF LOCD ONLY &S3 Off 5 sec after disconnect (SW56 only)
4=OFF TEST ONLY &S0_C0 Off for test only
5=OFF TEST+OOS &S1_C0 Off for test and OOS
6=OFF TEST + LOCD &S5 Off 5 sec after disconnect or test.