Specifications
40
CSU/DSU MS DBU
V.25
BIS
C
OMMANDS
When configured for the V.25 bis option, the CSU/DSU MS DBU accepts in-band
dialing and configuration commands from both synchronous and asynchronous
DTE ports.
The V.25 bis option supports the following protocols:
• SDLC
• Bi-Sync
• Asynchronous
SDLC Option
Character Format
• Data bits - 8
• Parity bit - Ignored
Command Structure
[F][A][C][V.25 bis COMMAND][FCS][F]
The address field [A] is FFH. The control field [C] is set to 13H except for cases of
multi-frame responses. For this case, the control field is set to 03H in all but the last
frame. The 03H in the control field indicates that other frames are to follow, while
the 13H in the control field indicates the final frame.
Bi-Sync Option
Character Format
• Data bits - 7
• Parity bit - Odd
Command Structure
[SYN][SYN][STX][V.25 bis COMMAND][ETX]
Asynchronous Option
Character Format
• Start bit - 1
• Data bits - 7
• Parity bit - Even
• Stop bit - 1
Command Structure
[V.25 bis COMMAND][CR][LF]