Specifications
28
CSU/DSU MS DBU
VT100 Terminal Connection and Operation
To control the CSU/DSU MS DBU using a VT100 terminal:
1. Select a terminal interface through the front panel. Select 3 CONFIG,
5 MANAGEMENT, 1 INTERFACE, 1 TERM CONTROL.
2. Set the CONTROL RATE to match the VT100 terminal.
3. Using the provided VT100 terminal adapter cable, connect the COM port
of a VT100 compatible terminal or equivalent to the eight-pin modular jack
labeled CONTROL on the rear of the CSU/DSU MS DBU. This connection is
used for both local and remote configuration.
4. Establish the connection and press Enter repeatedly until the Terminal Menu
appears (Figure 3-3).
5. Make selections by entering the number corresponding to the chosen
parameter. Press ESC to return to the previous screen.
NOTE
Due to the increased display capabilities, the VT100 menu structure
differs from the front-panel interface. Appendix C includes the VT100
screens as well as a complete menu tree for accessing configuration
selections. Descriptions of individual menu options are provided
throughout this manual based on the front-panel menu structure. See
Figure 5-1 for the front-panel configuration menu tree.
When establishing a TELNET session, the system prompts for a
password. The default password is “blackbox.” This password can be
modified through the Management menu. See Chapter 10 for more
information.