User's Manual

Page 9
724-746-5500 | blackbox.com
Chapter 4: TL500A Program Registers
4. TL500A Program Registers
The TL500A has been designed to perform several operations that are integral to
the proper function of your total communications system. The operations are
controlled by programmable information that is stored in files calledregisters.
Each register contains enough memory to hold factory preset default values
and “custom” values that allow the TL500A to operate to your specifications.
The following is a short description of each register function, program capacity,
and factory preset default values.
REGISTER 01 Mode Flags
This register controls eight features or operating modes performed by the
TL500A. Each “flag” or feature can be turned on/off and is programmed as a
string of bit information. Zero (0) denotesoff” and one (1) denotes “on.
NOTE: When programming this register, you must enter all Flag (Bit) values.
The Mode Flags are factory preset to the following:
Register 01 — Mode Flags
Flag Function Value Description
Flag 1 (Bit 7) Caller ID Store and
Forward
1 (on) CID will be captured when unit
answers. CID data will be sent
one time, after the first ring,
when a device port is
addressed.
Flag 2 (Bit 6) Fax Tone Detect to
Device 2
1 (on) If fax tone is detected, call will
be transferred to device 2.
Flag 3 (Bit 5) Night Watch Mode 0 (off) Allows calls to automatically be
transferred to the specified
port if not answered within a
certain number of rings.
Flag 4 (Bit 4) Additional Detect
Time
0 (off) Increases the time in which
tones can be detected before
ringing the default port by 4
seconds.
Flag 5 (Bit 3) Protected Hook
Flash
0 (off) For any KSU that does not
allow DTMF once a call is
answered.