March TL500A 2009 codes codes codes codes codes codes Phone Line Sharing Device Programming Manual Out-of-band network switch and call router— eliminate up to four phone lines.BLACK BOX ® Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 • Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 • Web site: www.blackbox.
Trademarks Used in this Manual Trademarks Used in this Manual Black Box and the Double Diamond logo are registered trademarks of BB Technologies, Inc. Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners. Page 2 724-746-5500 | blackbox.
FCC and IC RFI Statements/NOM Statement FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication.
NOM Statement 5. El aparato eléctrico no deberá ser usado cerca del agua — por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc. 6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante. 7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante. 8.
NOM Statement 17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación. 18.
Table of Contents Table of Contents 1. Specifications.....................................................................................................7 2. Overview............................................................................................................8 3. TL500A 2.0 General Operation..........................................................................8 4. TL500A Program Registers.................................................................................
Chapter 1: Specifications 1. Specifications Technical Specifications Power 110–125 VAC, 50–60 Hz, 2.5 Watts (idle), 4 Watts (ringing). REN 1.1B Dimensions 1.5"H x 6.25"W x 9.5"D (3.8 x 15.9 x 24.1 cm) Warranty 2 Years 724-746-5500 | blackbox.
Chapter 2: Overview/Chapter 3: TL500A 2.0 General Operation 2. Overview The TL500A can be easily tailored to fit the needs of individual organizations or departments. A wide variety of remote site information systems can be accessed, and with its register programs, the system functions can be configured to meet the specifications of both calling and receiving modems and long distance switching time.
Chapter 4: TL500A Program Registers 4. TL500A Program Registers The TL500A has been designed to perform several operations that are integral to the proper function of your total communications system. The operations are controlled by programmable information that is stored in files called “registers.” Each register contains enough memory to hold factory preset default values and “custom” values that allow the TL500A to operate to your specifications.
Chapter 4: TL500A Program Registers Register 01 — Mode Flags (Continued from previous page) Flag Function Value Description Flag 6 (Bit 2) Busy Signal 1 (on) Determines if a device trying to access the line when the line is already in use will hear a busy tone or dead air. Flag 7 (Bit 1) Enable Multi-Port Polling 0 (off) Allows transfer to another device when communication with the first device addressed is complete.
Chapter 4: TL500A Program Registers REGISTER 06 — Night Watch Mode Rings This Register contains the number of rings to the phone device port after Night Watch Mode (Register 05) has been activated. This number is usually less than register 05 but can range from 1 to 15. Factory preset is 2 rings. REGISTER 07 — Emergency Barge In This register contains the mask that determines if Devices 1, 2, 3, and 4 can barge in and gain access to the telephone line by going off-hook during a call.
Chapter 4: TL500A Program Registers REGISTER 11 — Security Access Code for Device Port 1 Contains the security access code for device port 1. This register holds up to 7 digits ranging from 0 to 9, * and #. Factory preset to 11. REGISTER 12 — Security Access Code for Device Port 2 Contains the security access code for device port 2. This register holds up to 7 digits ranging from 0 to 9, * and #. Factory preset to 22.
Chapter 4: TL500A Program Registers REGISTER 29 — Security Access Code for Device Port 9 Contains the security access code for device port 9. This register holds up to 7 digits ranging from 0 to 9, * and #. Factory preset to 99. WARNING: For registers 11 through 15 or 26 through 29, DO NOT program any of the security access codes to segments of the programming code (**7764#).
NOTES Page 14 724-746-5500 | blackbox.
NOTES 724-746-5500 | blackbox.
Black Box Tech Support: FREE! Live. 24/7. Tech support the way it should be. Great tech support is just 30 seconds away at 724-746-5500 or blackbox.com. About Black Box Black Box provides an extensive range of networking and infrastructure products. You’ll find everything from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free, live 24/7 Tech support available in 30 seconds or less. © Copyright 2013. Black Box Corporation.