User`s guide
BLACK BOX® CS Installation, Administration, and User’s Guide 91
3. To change the parity, select “None,” “Odd” or “Even” from the “Parity”
pull-down menu.
The default is “None.”
4. To change the baud rate, select an option from 2400 to 921600 Kbps from
the “Baud Rate” pull-down menu.
The default is 9600, which is the most common baud rate for devices.
5. To change the data size, select an option from 5 to 8 from the “Data Size”
pull-down menu.
The default is 8.
6. To change the stop bits, select 1 or 2 from the “Stop Bits” pull-down
menu.
The default is 1.
7. To change whether authentication is required, check the “Authentication
Required” checkbox for enabled or leave it unchecked for disabled.
8. Select “apply changes' to save configuration to Flash.
9. Select the “Next” button or proceed to the next section, “Step 4: Access.”
Step 4: Access
Selecting “Step 4: Access” brings up a form shown in the following figure,
which allows you to add or delete user accounts, and set or change existing
passwords.
In addition, administrative privileges can be granted to added users by adding
the user accounts to an “admin” group, enabling them to administer the
connected devices without the ability to change the configuration of the CS.
By default any user can access any port as long as they have a valid user ID
and password.