Troubleshooting guide
  6 
Indicator Lights 
Main Logic Board: 
1.  Green LED on: AC power applied to the logic 
board. All fuses are good. 
2.  Red LED 
A.  Heartbeat - 5 and 12vdc present. The changer is in 
standby waiting for a bill pulse. 
B.  On Steady - Out of service, Hopper error detected. 
Validator logic board: 
1.  Red LED 
A.  On Steady - Standby Mode, waiting for bill 
insertion. 
B.  Flashing - Error mode, go to page for error code 
information. 
C.  Off - The changer “Empty” LED is lit. 
WIRE HARNESS COLOR AND DEFINITIONS 
Validator harness: 
Red -  Switched Hot 120VAC. 
White -   Neutral 120VAC. 
Black -  120VAC Low current validator enable. 
Yellow -   +5vdc credit pulse line. 
Blue -   -5vdc credit pulse line. 
Orange -   +12vdc Empty LED. 
Brown -  -12vdc Empty LED. 
Hopper Harness 
Yellow -  Coin counting optic status line. 
White -  Low coin sense (+5vdc). 
Brown -  Low coin sense (-5vdc). 
Black(s) - - 24vdc Motor supply voltage. 
Orange -  +24vdc Motor supply voltage. 
SETTINGS FOR THE AC400 ONLY! 
AC500 ONLY! 
CoinCo MAGPRO Series Flash Codes 
Flash codes 1-18 may appear during normal servicing of the 
BA30. If more than one error or condition exists, the lower 
number flash code will appear until its respective error or 
condition is corrected. The left and right sensors referenced 
below are given viewing the BA30 from the front. 
# of Flashes  Description of Flash Codes 
1  Bill box full 
2 N/A 
3  Check bill path 
4  All bill accept switches are off 
5  Bill jam or sensor error 
6  Stacker motor/home sensor 
7  Transport motor/encoder sensor 
8 N/A 
9  EPROM Has Failed 
10  EPROM Has Failed 
11  Center Optic Failed 
12  Right Optic Failed 
13  Left Optic Failed 
14  Bill Position Sensor Error 
15  Right Bill Position Sensor Error 
16  Left Bill Position Sensor Error 
17  Lower Anti-Stringing Armature out of place 
18  Upper Anti-Stringing Armature out of place 