Lighting the fire with the Manual Switch.
There is an optional wall switch. This is a manual switch
membrane which can be stuck to the wall. Please ensure that the
switch and cable do not become detached during assembly. Refer
to the remote fault diagnosis if the unit “beeps” repeatedly. If the
switch is not to be used the remote “link” must be fitted to the
remote black box. The fire will not operate without either the
switch or the link.
Button #1 - By pressing this switch, this starts
the ignition sequence (press & hold for 3 sec
minimum). The gas to the pilot is open and the
magnet unit pressed by the motor, the spark is
generated. When the pilot flame presence is
detected the system holds for 10 seconds to
warm the thermocouple.
Once the thermocouple is warm enough to hold
the magnet unit the valve will allow gas to the
burner at the maximum setting.
In case of failure during pilot ignition sequence,
the EDB puts the system in safe mode. To
restart the ignition sequence press Button #1
again.
It is possible once the fire is lit to operate in
standby mode with pilot only lit. To do this press
button #2.
By pressing Button #3 the burner flame is
increased to the maximum rate.
By pressing Button #4 the burner flame can be
reduced to the minimum rate. This may involve
pressing the switch a number of times in steps
to get the lowest setting.
To turn the appliance OFF Button #1 is pressed.
Each time a button is pressed a “beep” will be
heard.