Technical data

Page 42 of 52
Appliance Start Up / Shut Down Instructions
(Lighting the Fire)
The appliance is supplied with an internal battery power supply and is operated
via handset. There are 6 x ‘AA’ batteries inside the appliance and 1 x 9V
battery in the handset. Only use good quality batteries to ensure a long life.
If the main burner or pilot light is extinguished during lighting, do not attempt
to re-light the pilot within three minutes.
To Reset the Appliance:
If the appliance is shut down unexpectedly the valve must be reset first before
the fire can be re-lit. This can be done by pressing the “OFF” (button #1) until
a beep is heard. Wait a few seconds then commence the starting sequence as
detailed below by pressing both left had buttons at the same time.
Using the Handset (see image).
• To Light the Fire – As a “child proof” system both buttons #1 & #2
must be pressed at the same time for a number of seconds until the ignition
(spark) sequence starts. To operate correctly the handset must be pointed
directly at the magic eye on the appliance. When the pilot flame presence is
detected (ionization flame control) the system holds for 10 seconds to warm
the thermocouple. Once the thermocouple is warm enough to hold the
magnet unit the valve will allow gas to the burner at the maximum setting.
• In case of failure during pilot ignition sequence, the EDB puts the system
in safe mode. To restart the ignition sequence press Button #1 again.
• Standby Mode - It is possible once the fire is lit to operate in standby
mode with pilot only lit. To do this press button #2.
• High Setting
- By pressing Button #3 the burner flame is increased to
the maximum rate.
• Low Setting - By pressing Button #4 the burner flame can be reduced
to the minimum rate.
• Turn Off - To turn the appliance OFF Button #1 is pressed.
Each time a button is pressed a “beep” will be heard.