Technical data

Page 31 of 52
Servicing Procedure
Turn off the fire and allow cooling time.
Turn off the gas supply at the isolation tap.
Remove the fascia.
Using a Phillips style screwdriver, loosen the screws on the mixer tube
then undo the injector nut, and remove the injector.
Clean the injector and remove blockages. Do not use a needle or wire, as
this may widen the journals, which are set to the C V O test standards.
Using a soft brush or vacuum cleaner, carefully remove any debris from
the burner unit.
Make sure the pilot journals are clear and free from dirt.
Re-assemble the fire in the reverse order, and re-connect the gas supply
then check for soundness.
Check the pilot for a good flame.
Re-commission the fire (See section earlier in this booklet).
For Spare Parts please call 01325-327221 and ask for customer
service.
Spare parts are not returnable. CVO Fire cannot accept responsibility
for incorrect parts being ordered. When ordering replacement components
or requesting technical assistance, you should at all times quote the following:
Type of fire & Gas supply (LPG or NG) as shown on Data Plate
Unit serial number as shown on Data Plate or front of booklet.
Component part number or description of fault