Service and Aftercare Requirements
When completing the annual service of the unit, refer to the enclosed
technical installation and operational manual & the remote control
instruction document.
The gas unit should be installed to the manufacturer’s instructions by a Gas
Safe registered gas installer, every 12 months the gas fire unit should undergo
a regular service, this work should be carried out by a competent person who is
Gas Safe registered, familiar with the CVO Fire range of goods.
When carrying out the annual service, the competent person should
examine and verify the following;
• The correct safe operation of the ODS (oxygen depletion system)
• That the fire unit correctly cross-lights
• A pressure drop test to verify that there are no gas leaks
• That the electronic ignition system operates correctly
• That the burner surface is free from damage and debris
• That the owner has a copy of the installation and operation manual
Servicing Instructions
General
CVO Recommend that this appliance is serviced every 12 months by a
GAS SAFE Engineer.
The following servicing procedure should be carried out regularly and only by a
qualified person.
Note: foreign bodies, which can gather on the surface of the burner unit, it is
inevitable that servicing can be a dusty operation. Suitable precautions should
be taken.
Important: The pilot and flame sensing device fitted to this fire is also
an atmosphere sensing device. If for any reason any part of the pilot
assembly is to be replaced, the entire assembly including the pilot
burner, thermocouple electrode and injector must also be exchanged.
This atmosphere sensing device is not adjustable and must not be
disabled.