Battery Remote System – Alarm Sequence
This fire is operated via a battery remote system with AA batteries. The
remote system has a built in alarm system which indicates and faults
which may arise. This is shown by a sequence of a pre-defined number of
“beeps” corresponds to a certain failure.
BLACK BOX – IR
Alarm sound description
3 x beeps – Manual Wall Switch Keyboard Failure
Substitute the keyboard with another one and verify the sound alarm
stops.
4 x beeps – Valve Motor Failure
Substitute the valve with another one. Repeat the ignition sequence and
verify the sound alarm stops.
5 x beeps – Driver Leakage [Black Box Faulty]
Substitute the board: the motor drive circuit is damaged. Execute an
ignition sequence and verify there’s no sound alarm.
6 x beeps – Under Voltage Low battery
Substitute the battery with a new one and verify the sound alarm stops.
Before inserting the new battery pack, remove the old one and wait until
the sound disappears. Wait at least 2 minutes before adding the new
batteries. If the sound is still present after adding new batteries, execute
an ignition sequence.
7 x beeps – Low Battery
Substitute the battery with a new one and verify the sound alarm stops.
Before inserting the new battery pack, remove the old one and wait until
the sound disappears. Wait at least 2 minutes before adding the new
batteries. If the sound is still present after adding new batteries, execute
an ignition sequence.
Only use high quality Alkaline or Lithium batteries in the appliance and
hand set to ensure a long and reliable life. NEVER USE old batteries, the
set must be replaced as a complete set of new batteries.