Symptom Check List Tick
The system “beeps”
all the time.
There is a fault diagnosis system built into the battery remote. The remote
gives out a sequence of “beeps”. This is a code which indicates a fault. See
page 29 for alarm sequence.
Check spark lead is connected properly.
Appliance clicks but
no spark or weak
spark.
Check spark electrode is in the correct area and the gap correctly distanced
to the pilot.
Check for a good spark. Check the spark is in the right area.
Check that the ventilation is not too strong and drawing the gas away from
the
p
ilot.
Appliance sparks but
does not light pilot.
Check that there is gas at the input and at the pilot.
Check that remote valve is o
p
eratin
g
correctl
y
.
Check isolation tap/shut off is open.
If there is no gas.
Check for blockages in the gas pipes.
Check for a good spark.
Check the spark is in the right area.
Check that the ventilation is not too strong and drawing the gas away from
the
p
ilot.
If there is gas but
pilot does not light
Check the pilot gas slot is clear.
Check the pilot flame is heating the thermocouple.
Check the thermocouple nut is properly tightened into the valve.
Check that the pilot lights early on ignition clicks.
Pilot lights but does
not light main burner
Check ventilation is not too strong and drawing the pilot flame away from
the thermocou
p
le.
When using LPG Bottles ensure bottle is not empty. To run this appliance on
bottles a minimum of 2 x 47KG bottles with a changeover valve is required.
The bottles must have a suitable regulator.
Check thermocouple nut is properly secured to the valve.
Check ventilation is not too strong and the flame is not blowing off the
thermocouple.
Burner lights but
turns off after a few
minutes
Check gas pressure is correct and maintained at constant level – especially
with other appliances in the home working.