Technical data

Page 25 of 52
Burner Flame
The flame on this type of appliance is normally directed towards the rear of the
enclosure. This is normal due to the opening size and flue system. The flame
will never stand “upright”. It is to be expected that over time the surface on the
rear of the enclosure will tarnish. This is typical “wear and tear” for a gas fire.
If the flame is drawn under the shelf this highlights a serious installation fault
and the appliance must not be operated until the cause is found. A typical
cause would be unsealed burner holes or failure to seal the enclosure and flue
(flame reversal). Any resulting damage is not covered by the warranty which
covers “defective” parts only.
Warning: Fire Guards & Hearths
This appliance is not fitted with an integral guard. In normal use
consideration may be given to the use of a fireguard conforming to
BS6539 or BS6778, so that the approach to the appliance is limited
such that access to the flame is minimised
It is recommended that a fireguard conforming to BS6539 or BS6778 is used
for the protection of young children, the elderly and infirm.
The installer is to advise the user not to stand too close to the appliance for
prolonged periods of time and warn that loose clothing is particularly at risk of
burning due to the presence of an unguarded flame.
In addition, the installer is to advise the user against placing combustible
material directly in front of the appliance. Floor coverings, such as carpets, are
considered to be acceptable.
For some countries a non-combustible hearth must be fitted in front of the fire
in accordance with National Regulations (e.g. United Kingdom).