Technical data

Page 24 of 52
Oxygen Depletion Pilot System
There is a highly sensitive oxygen depletion sensor designed into the pilot light.
If any part is damaged the entire unit must be replaced. Do not attempt to
bend or alter the flame head, thermocouple or aeration hole. Use only genuine
spare parts as similar looking parts from other appliances may well give
different or inferior performance and could lead to a hazard.
Spark / Ignition Failure
The gap between the pilot electrode and the pilot should be 3.5 – 4.5mm and
normally adjustment is not necessary (the electrode is very brittle). The spark
should jump across the gap between the electrode and the gas outlet on the
pilot head. If the ignitor fails, a lighted taper can be inserted into the pilot area
to check that gas is reaching the pilot.