Fitting the Metal Fascia
The trim is optional and can be fitted after the fire is completed by using the
two lower and two upper screws which secure it to the enclosure. The trim
should be floating on the wall, not recessed into it.
Seal the Flue and Check Burner Ventilation
See Page 14 “burner ventilation” before proceeding.
This appliance requires a specific amount of ventilation to function as designed
(correct flame picture), therefore any unused utility access points in the burner
tray must be sealed with Aluminium foil tape.
When installing the enclosure into an existing chimney or with a flue liner the
enclosure & gather must be sealed to the existing chimney to ensure that air
cannot flow behind the enclosure (flame reversal). Failure to do this will result
in serious damage to the burner unit and enclosure. This damage is not
covered by the warranty.