Technical data

Page 10 of 52
General Installation Information
This fire is intended for decorative purposes. The installation must be in
accordance with National Regulations and must be carried out by a qualified
installer.
Clearances between the fire and all combustible materials must conform to
National Regulations.
This fire must be installed and used in accordance with these instructions.
Prior to installation, ensure that the local distribution conditions (identification
of the type of gas and pressure and the adjustment of the appliance) are
compatible.
The builders opening or fireplace opening must be constructed of a non-
combustible material.
For some countries a non-combustible hearth must be fitted in front of the fire
in accordance with National Regulations (e.g. United Kingdom).
Any flue damper plate or flue restrictor must be removed or fixed permanently
in the fully open position, or shall only be fitted in accordance with National
Regulations.
The chimney must be swept before the appliance is installed. The unit must not
be installed unless the chimney/flue length is at least the distance indicated on
page 3 (minimum flue height).
Before the fire is installed a flue test in accordance with National Regulations
should be carried out.
The gas connections must be in accordance with National Regulations.
An isolation valve, or valves, has to be fitted adjacent to the appliance which,
when closed, allow(s) the complete burner and control assembly to be
disconnected for maintenance or repair in accordance with National
Regulations.
The pilot light and flame sensing device fitted to this fire is also an atmosphere
sensing devise. If for any reason any part of the pilot assembly is to be
replaced ALL the assembly including the pilot burner, thermocouple, electrode
and injector must be exchanged complete for an original manufacturer’s pilot
assembly only. This atmosphere sensing devise is not adjustable and must not
be put out of action. The pilot light shuts off both the main burner and pilot if
evacuation of the combustion products is interrupted. If the fire shuts itself off,
do not use the fire, and have the flue and fire checked by a suitably qualified
person.