Technical data
Page 7 of 44
Power Supply
Read through this section before starting the installation
The installation should only be carried out by a CORGI registered
installer and in accordance with national and local regulations for
both gas and electricity.
Power Supply 230v AC-15%+10%, 50/60 Hz
Max power consumption 20VA cos 0.6 (Peak)
Stand-by power consumption 1W
Ambient Temperature 0.80 C
Protection IP 20
Humidity Max 95% at 40c
Electrical protection Not required
Connections STELVIO/STOCKO
Waiting time for demand 3-5 seconds typically
Ignition Time 20 seconds typically
Ignition Frequency 1Hz
Spark gap Max 6mm
Ignition Cable length 500mm
The black lead is the electrical feed to the burner, a 3 amp fused spur located
wherever convenient is to be connected between the power supply and the
burners black lead. The Grey or white wire is connected to the hardwire
switch which if used, can be positioned as required. NOTE- DO NOT connect
the Hardwire switch to the mains, as this will damage the unit.
A mains connection is required close to the fireplace-a 0.7m cable is provided
for this purpose with a special plug connected to the burner control box. A
3amp socket may be used, or a fused spur outlet can be purpose provided.
The colour code of the mains is as follows;
Green/Yellow - EARTH
Brown - LIVE
Blue - NEUTRAL
The appliance must be in a position so that the mains supply is accessible for
routine maintenance.
A 3amp fused should be fitted in the plug of fused spur.
WARNING – This appliance must be earthed.