Technical data
Page 8 of 56
Unpacking the Appliance
Read these instructions fully before proceeding.
• Parts Supplied:
o Black Steel Enclosure
o Black Steel Gather
o Gas Burner with Remote Control [Pre-Fitted to Enclosure]
o Installation Kit with Installation Booklet.
o Remote Hand Set
o Stone Sections : 13 Pieces in Total
o Mains Power Adaptor
The FIREBREAK involves a large number of heavy stone parts which must be
handled with great care. Carefully examine the carton for damage before
unpacking. If it is obviously damaged, consult the supplier over whether to
proceed.
Remove the fire and examine its general condition. Any damage or defects
must be reported “before” installing the appliance. No claims will be accepted
for damage after the appliance has been installed.
The complete installation of this appliance should only be carried out by a GAS
SAFE Registered fitter and in accordance with national and local Regulations
for both gas, electricity and building control. Failure to have the fire fitted by a
qualified person nullifies ALL guarantees.
For the Republic of Ireland, reference should be made to IS813 and ICP3 and
any guidance notes from Bord Gais.
NOTE: Great care should be taken when handling the stone as it can be easily
damaged.
If satisfied by the condition proceed with the installation.
Planning the Installation
1. Before starting to install this fire note that it requires:
a. A 240v Mains Supply
b. A Compatible Flue System (See Technical Data)
c. Room Air Ventilation of minimum 100cm2
d. A Strong Gas Supply (See Gas Supply)
e. Complete Installation by a Qualified Gas Safe Engineer.