Technical data

Page 39 of 56
Fitting Spare Parts
There are no “user” replacement parts available for this fire.
Spare parts are not returnable. CVO Fire cannot accept responsibility
for incorrect parts being ordered. When ordering replacement components
or requesting technical assistance, you should at all times quote the following:
Type of fire & Gas supply (LPG or NG) as shown on Data Plate
Unit serial number as shown on Data Plate or front of booklet.
Component part number or description of fault
The fitting of replacement parts must be carried out by a qualified GAS SAFE
Engineer inline with current regulations. When removing any parts from the
remote system these should be replaced in the same manner using the
“schematic diagram” in this booklet. When changing the injectors or pilot great
care must be taken to assemble the parts in the correct manner to ensure the
fire functions as designed.
Burner Removal
Removal of the burner during installation will invalidate the warranty.
Speak to our technical department.
If the burner needs to be removed at anytime for repair follow the
steps below:
Remove the front shelf.
Remove the 2 cross headed screws on each side which hold the front
shelf mounting brackets to the enclosure.
Disconnect the gas and electricity supply.
The burner carriage is screwed to the bottom of the enclosure by 2
screws. Once removed the full burner assembly will lift out.
Refit is the same procedure in reverse.
The fire should be commissioned once refitted.