Technical data

Page 37 of 56
Servicing Procedure
Turn off the fire and allow cooling time.
Turn off the gas supply at the isolation tap.
Remove the fascia.
Using a Phillips style screwdriver, loosen the screws on the mixer tube
then undo the injector nut, and remove the injector.
Clean the injector and remove blockages. Do not use a needle or wire, as
this may widen the journals, which are set to the C V O test standards.
Using a soft brush or vacuum cleaner, carefully remove any
debris from the burner unit.
Make sure the pilot journals are clear and free from dirt.
Re-assemble the fire in the reverse order, and re-connect the gas supply
then check for soundness.
Check the pilot for a good flame.
Re-commission the fire (See section earlier in this booklet).
For Spare Parts please call 01325-327221 and ask for customer
service.