Technical data

45
Error Limit Reached (254). Click on the Start Error Logging button to reset the
error counter. This message appears when monitoring Extender bus activity and
the number of errors across the bus have exceeded 254. It appears within the error
log window.
NOTE
Each error might not appear in the error log window. If a burst of errors
happens extremely rapidly, the log will not be able to capture and
display the error information. However, the counter will properly reflect
the actual number of errors across the bus up to 254.
Common reasons for the message:
Errors will occur any time the communication with the Extenders has been
disrupted. Thus, the following will create this message.
- Extender hardware is turned off.
- Communication port settings are not correct.
- Serial cable is unplugged from the PC or Extender hardware.
Fiber or Coax connection between the two Extenders is not functioning
properly or has been disconnected.
Link errors detected: #
This message appears on the main window when Error
Logging has been enabled and started on the Extenders. If the number is greater
than 0, then errors will also show up in the error-log display area.
CHAPTER 11: Error and Warning Messages