Hardware and
Included
Accessories
1, 2, or 4 Port Industrial Serial Server module
Manual: Paper copy of this manual, PDF available
CD-ROM disc: Serial Server Manager and Virtual COM Driver software
for Windows 98/ME/2000/XP/NT 4.0
Dimensions
1 or 2 Port: 1.75 x 6.1 x 4.1 in (4.46 x 15.52 x 10.46 cm)
4 Port: 1.75 x 7.1 x 4.1 in (4.46 x 18.03 x 10.46 cm)
Power &
Environment
Power Supply Voltage Requirements:
9V to 48 VDC or 8V to 24VAC
Power Consumption:
1 Port: 320mA @ 12VDC
2 Port: 340 mA @ 12VDC
4 Port: 360 mA @ 12VDC
Power supply startup time ≤24ms
Operating
Temperature: –10 to 80 °C
Storage
Temperature: –20 to 85 °C
Humidity: 5 – 98% R.H.
Approvals: CE, FCC, IP30 case
Indicators
Power: Red LED
Link: Yellow or green LED (10BaseT or 100 BaseTX)
Ready: Flashing green LED
Connectors
Ethernet: Single RJ-45 female
Serial: 1 Port Serial Server: one 9 pin D-type male (DB-9M)
and one removable terminal block (connector selectable
using DB-9/Terminal switch, interface type software
selectable as RS-232, RS-422, RS-485H or 485F)
2 Port Serial Server: Two 9 pin D-type male (DB-9M),
(interface type software selectable as RS-232, 422, RS-
485H or RS-485F
4 Port Serial Server: Four 9 pin D-type male (DB-9M)
DTE, (interface type software selectable as RS-232, RS-
422, RS-485H or 485F)
DC Power: Removable four terminal screw-type terminal block
Serial Server Technical Data
66 Chapter 12 Documentation Number: LES40xA-1105m
Black Box Corporation - 1000 Park Drive - Lawrence, PA 15055-1018
www.blackbox.com -- Tech Support and Ordering: 724-746-5500 - Fax: 724-746-0746
Serial Interfaces
RS-232(DTE): TXD, RXD, RTS, CTS, DTR, DSR, DCD, GND
(1 Port Serial Server terminal block option: TXD,
RXD, RTS, CTS, GND)
RS-422: TXDB(+), TXDA(−), RXDB(+), RXDA(−),
RTS(+), RTS(−), CTS(+), CTS(−) and GND
(1 Port Serial Server terminal block option:
(TXDB(+), TXDA(−), RXDB(+), RXDA(−), GND)
RS-485 H: Data B (+), Data A (–) and GND
RS-485F: TXDB(+), TXDA(−), RXDB(+), RXDA(−),
and GND
(1 Port Serial Server terminal block option:
(TXDB(+), TXDA(−), RXDB(+), RXDA(−), GND)
Baud Rate: 110 bps to 230.4 k bps
Parity: None, Even, Odd, Mark, Space
Data Bits: 5, 6, 7 or 8
Stop Bits: 1, 1.5 or 2
Memory
Serial Memory: 8K byte per port
Network Memory: 48K byte
I/P Port Addresses
5300 Heartbeat & Configuration setting in TCP Mode (i.e.
Pair Mode)
8888 Serial Server update
8890 Serial Server monitor
8889 Set configuration in UDP mode
Network
Communications
LAN: 10/100 Mbps Auto-detecting 10 BaseT or 100
BaseTX
Protocols
TCP, IP, ARP, DHCP, Telnet, HTTP, UDP, ICMP
Configuration
Options
Console Mode: Using RS-232 with VT100 emulation
Telnet Mode: Using HyperTerminal with VT100 emulation
Serial Server
Manager: Using Windows 98/ME/2000/XP or NT software
Web Server: Using Internet Explorer web browser
Optional
Accessories
Null Modem Crossover Cable for DTE to DTE connection
One-meter length of steel 35mm DIN Rail