Corporate Headquarters GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.com Magnum DS8016 10 / 100Mb Dual-Speed Stackable Hubs Installation and User Guide www . GarrettCom . com www . GarrettCom . com $5.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) Magnum™ DS8016 10/100Mb Dual-Speed Stackable Hubs Installation and User Guide Part #: 84-00120, Rev. C (04/01) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) The Magnum Line ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND MANUFACTURED IN THE USA" OVERVIEW GarrettCom, Inc.offers the premium-quality Magnum™ line of Ethernet LAN connectivity products with industry-standard functionality and built-in fiber configurability. Magnum products are designed for use in demanding Carrier Class, Industrial Grade and OEM applications where reliability is a primary consideration.
Magnum DS8016 Dual-Speed Stackable Hubs TABLE OF CONTENTS Installation and User Guide (07/06) PAGE 1 1.0 SPECIFICATIONS ................................................................................ 1 Technical Specifications ...................................................................... 1 Ordering Information ........................................................................... 3 2.0 INTRODUCTION .................................................................................. 4 2.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) Rev B 03/99 : Added Reverse model specifications and collision domain diameter, cable distances and pdv calculations Rev A 07/98 : This revision is the initial release of the DS8016 10/100 Dual Speed Stackable Hubs user manual. www . GarrettCom .
Magnum DS8016 Dual-speed Stackable Hubs 1.0 1.1 Installation and User Guide (04/01) SPECIFICATIONS Technical Specifications 100 or 10 Mb/s per port, auto-sensing for speed. DS8016 hubs support two traffic domains, one at 100Mb/s and one at 10Mb/s, have sixteen RJ-45 ports, and are stackable up to 3 units high operating as one repeater.
Magnum DS8016 Dual-Speed Stackable Hubs 48VDC Power Supply (Optional) Installation and User Guide (07/06) Power Input Voltage : 36 to 72 VDC (auto ranging) Terminal Block in rear: “-, GND, +” Power consumption: 25 watts typical, 40 watts max. P.S.
Magnum DS8016 Dual-Speed Stackable Hubs 1.2 Installation and User Guide (07/06) Ordering Information Magnum DS8016 Dual-Speed Stackable Hubs Magnum DS8016-A: Dual-Speed 10/100 Stackable Hub with sixteen RJ-45ports, each auto-sensing for 100Mb or 10Mb operation. Stackable up to three units high, with all ports in one stack operating as two separate traffic domains, one domain at 100Mb/s and one domain at 10Mb/s.
Magnum DS8016 Dual-Speed Stackable Hubs 2.0 2.1 Installation and User Guide (07/06) INTRODUCTION Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage which you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.
Magnum DS8016 Dual-Speed Stackable Hubs 2.2 Installation and User Guide (07/06) Product Description - General Magnum DS8016 Dual-Speed hubs have sixteen RJ-45 ports, each 10/100Mb auto- sensing *. Each port can independently identify (via IEEE 802.3u auto-sensing) and accept either 100Mb or 10Mb Ethernet signals, adapting to match the best speed of the connected device. There are two internal traffic domains in Magnum DS8016 hubs, one for the 100Mb traffic and one for the 10Mb traffic.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) Another DS8016 model, the DS8016-A, has no switch module inside, but is dual speed and is normally used stacked with a DS8016-B for dual-speed port expansion.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) LEDs to indicate operating status are on the front side. There are power (PWR) and bridge-inside (BR) indicators for the unit. There are collision (COL) indicators for each of the 10Mb and 100Mb domains, for visual indication of the operating status of each domain.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) 2.2.3: Magnum DS8016-E model, 100Mbps -only The Model DS8016-E is like the DS8016-A except that it’s speed is internally fixed at 100Mbps on all ports. It is not dual-speed. It has no bridge inside. It is used for 100Mbps-only applications, and it can operate stand-alone or stacked with the other DS8016B and DS8016-A models. Special orders of this model can be built with some ports fixed at 10Mb.
Magnum DS8016 Dual-Speed Stackable Hubs 2.3 Installation and User Guide (07/06) Stacking Magnum DS8016s Up to three Magnum DS8016s can be stacked to operate as one 10/100 dual-speed repeater with up to 48 dual-speed ports. Normally, one Magnum DS8016-B hub per stack is needed to provide a switched interconnection between the two separate 100Mb and 10Mb traffic domains in the stack. Additional stacked units are normally Model DS8016-A or -E “add-on” units, which cost less.
Magnum DS8016 Dual-Speed Stackable Hubs 2.4 Installation and User Guide (07/06) Bridge Module between the 10Mb and 100Mb Domains Bridge Module Figure 2.4 : Internal view of DS8016-B 10 BUS 100 with bridge module installed Magnum DS8016-B’s and DS8016-R’s contain a factory-installed bridge module to interconnect the two traffic domains, filtering and selectively forwarding packets to allow only necessary packets to cross between the domains.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) to cascade two DS8016 hubs or stacks together, the auto-sensing feature will cause the connecting link to operate at 100Mb speed. 2.6 Features and Benefits Supports 10 or 100Mb network connections on each of sixteen RJ-45 ports Magnum DS8016 Dual-Speed 10 / 100 hubs combine two logical hubs . . . one at 10Mb and one at 100Mb . . . in one physical box supporting two traffic domains.
Magnum DS8016 Dual-Speed Stackable Hubs 2.7 Installation and User Guide (07/06) Applications Example 1 : A Magnum DS8016-B serves a small office with mixed speed requirements. Some users operate at 100Mb, and some users and utility devices (such as print servers) run at 10Mb. All share the same hub, and talk to each other via the bridge module inside. Any node can change speed at any time without affecting network operation or impacting other users.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) Example 3 : For additional expansion, DS8016s can be expanded by stacking DS8016-A “addon” units. The additional stacked ports are all auto-sensing dual-speed domain-switched, and can be used at either 10Mb or 100Mb on a per-port basis. The stacking cables connect the DS8016 units and carry the signals for both the 100Mb and the 10Mb domains.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) Example 4: A Magnum DS8016-R serves a good solution for the user, who expect a high-availability, neat networking connection with clear visible display of LEDs port. Specially a place where existing network is supporting10Mbps user and want to expand the network with 100Mbps fast ethernet. Magnum DS8016-R equipped with bridge module provide a very effective and reliable solution for these users.
Magnum DS8016 Dual-Speed Stackable Hubs 3.0 Installation and User Guide (07/06) Magnum DS8016 Installation Before installing the equipment, it is necessary to take the following precautions: 1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment must be less than or equal to 500C. 2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate air flow must be maintained for proper and safe operation. 3.
Magnum DS8016 Dual-Speed Stackable Hubs 3.1.2 Installation and User Guide (07/06) Rack-Mounting Installation of a Magnum DS8016 Stackable Hub in a 19” rack is a simple procedure. The units are 1U (1.75”) high, including the rubber feet underneath. When properly installed, the front-mounted LED status indicators should be in plain view and easy to read. Rack-mount installation requires special rack-mounted brackets and screws (included with each DS8016).
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) 3.2.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shielded) The following procedure describes how to connect a 10BASE-T or 100BASE-TX twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted pair cables. 1. Using standard twisted pair media, insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) device component and the associated BT delay. A “DTE” is an end node, such as a user station. Note that there is only one DTE pair associated with any device-to-device path. Table 3.2.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) Cat. 5 cable for cascading where 111 is the BT delay for 100m of Category 5 cable (1.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) industry standards normally permit, and is different from what competitive 100Mbps Class II hub products normally allow. This additional cascading level and cable length is due to the relatively shorter bit time (80 BT actually measured, for front-port-to-port) delay of the Magnum DS8016 vs. the industry standard delay of 92 BT for Class II repeaters.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) VAC 60Hz power cord is supplied with each unit shipped within the United States and Canada. Each Magnum DS8016’s auto-ranging power supply supports installation environments where the AC voltage is from 90 to 260 volts with an input frequency between 47 and 63 Hz, and consumes a maximum of 27 watts.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) 10Mb Domain : 10Mbps packets are forwarded when the destination addresse is NOT in the 10Mb domain address table. 100Mbps Domain100Mbps : packets are forwarded when the destination address is NOT in the 100Mb domain address table. 10Mbps Domain :10Mbps packets are filtered when the destination address is in the 10Mbps domain address table.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) By selectively forwarding packets from each domain to the other domain based on its switching (bridging) logic, the domain-switched Magnum DS8016-B increases the available bandwidth for the users on both sides of the network. As shown in Figure 4.1, it keeps the local traffic on each side contained, preventing unnecessary packets and bad packets from traveling to the other domain and using up bandwidth needlessly there.
Magnum DS8016 Dual-Speed Stackable Hubs 4.2 Installation and User Guide (07/06) Auto-negotiation and speed-sensing All sixteen RJ-45 ports independently support auto-negotiation for shared 10BASE-T and 100BASE-TX modes. When the ‘100’ LED is flashing, it means that the corresponding port is sending out auto-negotiation pulses on that port. When a LINK connection is made, the other device should respond and both sides should agree to the speed being signaled.
Magnum DS8016 Dual-Speed Stackable Hubs 4.3 PWR : Illuminates GREEN to indicate AC power is applied to the unit. COL : Red LED Blinks intermittently when a collision occurs. BR : Bridge Module Indicator, On when 10/100 bridge module is installed (Model DS8016-B), Off when no bridge module is inside (DS8016A) 100/Auto : Speed LED per port. Steady On when speed is 100Mbps , Off when speed is 10Mb, flashing when auto-negotiating or when not connected (no LINK) : Activity LED per port.
Magnum DS8016 Dual-Speed Stackable Hubs 5.0 Installation and User Guide (07/06) TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments. The installation of Magnum DS8016 10/100 Dual Speed Stackable Hubs is a straightforward procedure (see INSTALLATION, Section 2.6); the operation is also straightforward and is discussed in Section 4.
Magnum DS8016 Dual-Speed Stackable Hubs 5.2 Installation and User Guide (07/06) When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a. The nature and duration of the problem; b. Situations when the problem occurs; c. The components involved in the problem; d. Any particular application that, when used, appears to create the problem; 2.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details). However, if the problem or condition causing the return cannot be duplicated by GarrettCom, the unit will be returned as: No Problem Found.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) APPENDIX B : Optional 48V DC Power Supply, Addendum B1.0 SPECIFICATIONS - FOR DUAL-SPEED DS8016 HUBS Power Supply (Internal 48 VDC Option) DC Power Connector: 3 terminals: “-“, “GND”, “+” Input Voltage: 36 - 70 VDC (auto-ranging) Power Consumption: Model DS8016: 25 watt typical, 40 watts max.
Magnum DS8016 Dual-Speed Stackable Hubs B4.0 Installation and User Guide (07/06) INSTALLATION This section describes the installation of the 48 VDC power source leads to the 48 VDC power terminal block on the Magnum DS8016s. (see figure below). _ Figure A4.1: 48 VDC Terminal GND + ON Block on Magnum DS8016-48VDC OFF The 48 VDC terminal block on the Magnum DS8016s is located on the rear of the unit and is equipped 36-70VDC with three (3) screw-down lead posts.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) APPENDIX C: Optional 48V Dual-Source DC Power, Addendum C1.0 SPECIFICATIONS - FOR MAGNUM DS8016 DUAL-SPEED HUBS Power Supply (Internal, 48VDC Dual-Source model) DC Power Connector: First Source: “A+”, “A-“, 2nd Source “B-“, “B+” GND: Terminal for “earth” or ground wire connection to the hub chassis Input: Two separate sources, each at 36 - 70 VDC (auto-ranging) Power Consumption: Model DS8016: 25 watt typical, 40 watts max.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN a) The hub can receive power from either input, “A” or “B”. The hub will normally draw its power from the DC source with the highest voltage (in the 36-70V range) at a given time. b) The hub will not allow power to flow from a higher voltage input to a lower voltage input, i.e. the two DC power sources are not mixed together by the hub.
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06) Operation of the Dual-Source Magnum DS8016-48VDC hub models is identical to that of the standard models. Please refer to the applicable sections of the “Installation and User Guide” for more information on the basic hubs. www . GarrettCom .