Specifications
Model AC1120A, AC1121A, AC1122A, AC1123A
30
3.2.12.1 IP Setup Commands using the RS-232 Serial Port
IP interface on the matrix has a unique MAC-address, and it must be assigned a
valid IP-address to function properly on the network. As shipped from factory this
IP is 192.168.123.180
1. To get into the IP setting mode:
Note: Inactivity period of 16 seconds causes the system to exit this mode. You can also hit
ESC to end the IP setting mode.
Command: IP <cr> stands for IP setting mode
Response:
Enter IP commands:
This is the normal response meaning that IP setting through the RS-232 port is
allowed
- - - - - Alternate Response - - - - -
IP commands not enabled. Please refer to the manual
This message indicates that IP setting through the RS-232 port is disabled on your
unit. Please refer to section 3.2.12.2 below to enable this mode
2. To get the current IP address of the matrix box:
Command: GIP <cr> stands for Get IP address.
Response:
192.168.123.180
3. To set a new IP address:
Command: SIP192.168.123.179 <cr> stands for Set IP address.
Response:
OK ..................................................... if command completed successfully.
Error ...............................................................................if command failed.
4. To get the current gateway IP address:
Command: GGI <cr> stands for Get Gateway IP address.
Response:
192.168.123.122
5. To set a new gateway IP address:
Command: SGI192.168.123.125 <cr> stands for Set Gateway IP address.
Response:
OK ..................................................... if command completed successfully.
Error ...............................................................................if command failed.