Specifications
ES10 Page 92/100
Document status: Released Operating Manual rev. 07, 25.09.13
After successful log-in, the warning and alarm thresholds for the RF
rms
input level, OMI
totrms
, RF
gain and optical output power can be set by the customer.
It is recommended to be very careful in setting the alarm thresholds in order to avoid meaningless
alarms, e.g. due to temperature changes. For the output power warning a range of at least +/- 1
dB is recommended.
Note:
The settings range for the alarm thresholds for RF input, RF gain and OMI
totrms
might change
slightly from device to device due to production tolerances.
Fig. 6.6.2: Limits-2 menu of ES10
Note: All settings of the limits-2 menu are factory settings only.