Specifications
Parameters
Output power Shows the optical Output power
RF Input power, total rms Shows the el. total rms input
power
If the el. input power is out of
range for the selected OMI- or
Gain-settings, a input warning
will be generated and the
showed value is not valid.
RF Input power, nominal Shows the nominal el. total rms
input power for specified
operation
RF Gain(only AGC mode) Shows in AGC mode the actual
Gain of preamplifier related to
nominal.
If the el. input power is out of
range for the required OMI
setting, a input warning will be
generated and the showed
value is not valid.
OMI total rms(only Manual mode) Shows for Manual mode the OMI
total rms related to nominal.
If the el. input power or the
selected gain is out of range
for a measurable OMI value, a
input warning will be
generated and the showed
value is not valid.
Laser Current Shows the Laser Current related
to BOL
Cooler Current Shows the Cooler Current related
to maximum
Module Temperature Shows the internal temperature
For actualization of values just go back to the OVTX menu and enter again
Voltages Show the device's internal voltages
Properties Show device's properties like
software- and hardware releases
and dates
Miscellaneous Generateing a reset or a reset to
default settings
Aliasname Change device's aliasname
6 MAINTENANCE
• Clean connector ends with a lint free tissue and alcohol before every mating.
• Loose screws fixing the optical connector plate
• Remove the connector from the connector bulkhead.
• Clean the connector ends with a lint-free tissue and alcohol.
• Reinstall the connector into the bulkhead ensuring that the cables/fiber´s are not
stressed.
Funea Broadband Services bv product information page 27 of 31
version: 11-02