Specifications
4.3 Front Panel
Figure 4.1 shows an example of the front panel view of the ES10. The RF-input and the
optical connectors are optionally available on the rear panel. The handles can be
omitted on request.
Item # Function
1 RF-input (optionally available on rear side)
2 RF-monitor output
3 Status LED’s
4 Liquid Crystal Display
5 Push button field for local set-up of transmitter
6, 7 Optical connectors (optionally available on rear side)
4.4 Rear Panel
The rear panel provides several field replaceable units:
4
4
Item # Function
4
power supply + fan modules
RF-input (optional on front panel)
1,2 optical fiber outputs (optional on front panel)
RS485 interface (RJ-45 female)
RS232 interface (SUB-D9 male)
Ethernet interface (RJ-45 female)
2 green LED’s (Ethernet link & data)
4.5 Power supply and fan modules
There are 3 different types of power supply and fan modules available for the ES10. All
of them can be either mounted on the left hand or right hand side,
It is possible to replace or exchange all of the modules during operation. This offers a
big flexibility to the end user in order to customise the ES10 exactly to the actual needs.
4.5.1 100 – 240 VAC module
Figure 5.3.1 gives the view on the 100 – 240 VAC power supply and fan module. There is
a AC mains input. There is one LED informing about the status of the power supply
module. The power unit O.K. LED is lightening green provided that the power supply
module is working properly.
The power supply and fan modules my be exchanged during operation (hot plug-in
technology) with having neither harm to the equipment nor having any impact on the
operation of the transmitter in case of a properly working backup power supply.
Funea Broadband Services bv product information page 17 of 31