Doughnut Fryer MODELS DNF, DNF-F Service Manual Serial Numbers 123439 and higher CS-TM-020.
BKI LIMITED WARRANTY 2812 Grandview Dr.
Doughnut Fryer Table of Contents Table of Contents Table of Contents ........................................................................................................................................1 Introduction..................................................................................................................................................2 Safety Precautions ............................................................................................................................
Doughnut Fryer Introduction Introduction The BKI Doughnut Fryer is intended for general commercial use. It consists of an oil vat, 2 electrical control panels, a manual drain control and an oil filter system (DNF-F only). The oil vat holds the cooking oil that is heated by tubular heating elements. The Lower Electrical Panel controls and indicates power to the unit as well as power to the filter system. This panel also contains 2 fuses that protect the circuitry within the unit.
Doughnut Fryer Introduction Safe Work Practices Beware of High Voltage This equipment uses high voltage. Serious injury can occur if you or any untrained or unauthorized person installs, services, or repairs this equipment. Always Use an Authorized Service agent to Service Your Equipment Noncombustible Floors Only Make sure your floor is noncombustible. Do not operate your fryer on floors that are wood, carpeted or have rubber mats. • Placing your fryer on a combustible floor could cause a fire.
Doughnut Fryer Introduction Keep The Lid Closed When The Fryer Is Not In Use Hot shortening can splash if someone moves the fryer or bumps into it. Serious injury can occur if hot shortening splashes out of the fryer. Do not lean, sit or stand on the fryer or perform any maintenance or cleaning duties while the fryer or the shortening is hot. You could be burned. Keep The Casters Locked To avoid spilling shortening, keep the casters locked.
Doughnut Fryer Introduction Wear Safe Clothing Appropriate To Your Job Always wear your insulated mitts when handling the racks or touch any hot metal surfaces. You received a pair of insulated mitts with your fryer. If you lose or damage your mitts, you can buy new ones at your local restaurant equipment supply store or from your local BKI Distributor. Always wear non-skid shoes when working around the fryer or any other equipment that uses shortening.
Doughnut Fryer Introduction Keep Safety Labels Clean and in Good Condition Do not remove or cover any safety labels on your equipment. Keep all safety labels clean and in good condition. Replace any damaged or missing safety labels. Refer to the Safety Labels section for illustration and location of safety labels on this unit. If you need a new safety label, obtain the number of the specific label illustrated on page 7, then contact: BKI Technical Services Department 2812 Grandview Drive Simpsonville, S.
Doughnut Fryer Introduction Safety Labels 7
Doughnut Fryer Installation Installation Serious injury, equipment damage or death could result if attempting to install this fryer yourself. Ensure that an authorized BKI service agent installs the fryer. Unpacking and Handling It is the owners’ responsibility to file all freight claims with the delivering truck line. Inspect all cartons and crates for damage as soon as they arrive.
Doughnut Fryer Installation Initial Test and Adjustment 1. Fill vat with shortening to about one inch below the mark. NOTE: A solid type vegetable shortening is recommended for frying because doughnuts tend to absorb more shortening and are heavy when fried in liquid shortening. Overfilling the fryer vat with shortening could lead to serious injury. Ensure that the fryer vat is filled with shortening only to the fill mark when shortening is hot.
Doughnut Fryer Replacement Parts Replacement Parts Use the information in this section to identify replacement parts. To order replacement parts, call your local BKI sales and service representative. Before calling, please note the serial number, model number and voltage on the rating tag affixed to the unit. Assemblies & Components Figure 1.
Doughnut Fryer Replacement Parts Table 1.
Doughnut Fryer Replacement Parts Figure 2. Upper Control Panel Assembly Table 2. Upper Control Panel Assembly Parts ITEM # 1 2 3 4 5 6 7 PART # SB1828 T0022 T0009 S0073 N0240 K0030 B1050 C0024 * or C0025 * * - See Figure 1 (27).
Doughnut Fryer Replacement Parts Figure 3. Motor & Piping Assembly Table 3.
Doughnut Fryer Replacement Parts Figure 4. Drain Valve and Handle Assembly Table 4. Drain Valve and Handle Assembly Parts ITEM # 1 2 3 4 5 6 7 8 9 10 PART # D0060 MA18000508 F0253 F0254 FT0543 SP0034 C0672 CA0003 DNFFA018 S0073 QTY 1 1 1 2 1 2 1 1 1 1 DESCRIPTION VALVE, DRAIN SS BALL&PLT.CAR.
Doughnut Fryer Replacement Parts Figure 5. Lower Control Panel Assembly Table 5.
Doughnut Fryer Replacement Parts Figure 6.
Doughnut Fryer Replacement Parts Table 6.
Doughnut Fryer Replacement Parts Figure 7.
Doughnut Fryer Replacement Parts Table 7.
Doughnut Fryer Replacement Parts Accessories Accessory # Description Picture D0012 DOWELL, WOODEN 1/2X18" R0012 RACK, FRY SCREEN 17" X 25" R0019 RACK, 17 X 25 SUBMERSION SCREEN R0020 RACK, FRY SCREEN LIFTER G0052 INSULATED MITT 13" 20
Doughnut Fryer Wiring Diagrams Wiring Diagrams Refer to the table below to find the wiring diagram associated with your unit.
Doughnut Fryer Wiring Diagrams Figure 8.
Doughnut Fryer Wiring Diagrams Figure 9.
Doughnut Fryer Wiring Diagrams Figure 10.
Doughnut Fryer Notes Notes 25
12 Grandview Dr., Simpsonville, S.C. 29680, USA http://www.bkideas.com Made and printed in the U.S.A LI0257/0407 CS-TM-020.
Doughnut Fryer Notes REVISION HISTORY REVISION 01 DATE 03/22/13 REVISED BY KW 2 DESCRIPTION Initial Release-Supersedes all previous releases