Service manual
Combi-Oven Maintenance
25
Number Description Controller without
this feature
Comments
dd: 17 Steam generator sensor S, CVC Shows °C if Err if a defect occurs
dd: 18 Condensation sensor Shows °C or Err if defect occurs
dd: 19
Motor Speed
dd: 20 Oven door
Shows a symbol for door open or
closed and Err if a defect occurs.
Can be initialized by pressing
exhaust key if door is closed and
oven sensor normal
dd: 21 Water level in steam
generator
S, CVC Shows water level below min. and
max. Temperature key: water in )
CM and Core temperature key:
water out) ST
dd: 22 Thermal cutout, 305°C ON appears if OK, OFF if
interrupted or a wiring defect has
occurred
dd: 23 Thermal cutout, fan motor
ON appears if OK, OFF if
interrupted or a wiring defect has
occurred
dd: 24 Contacts in damper motor ON appears when the contacts
are connected and OFF if
interrupted
Replacement
Changing halogen lamps in oven compartment
Replace Oven Halogen Lamps with 12V, 20W maximum.
Remove the lamp glass by means of a screwdriver. Always use halogen lamps specially made for BKI
Combis. Never touch the lamp without first protecting your fingers with gloves or a piece of cloth.