Service manual

Combi-Oven Installation
16
Accessing the Set-Up Mode
Select the set-up mode by pressing key (4) and key (2) simultaneously for 5 sec. U1 appears in the time
display. Shift to the next setting (max. U5) by pressing key (2). The set-up mode can be
interrupted/closed any time by pressing key (12).
U1: Selecting Automatic Restart
Automatic restart
1 or 0 is shown in the time display (1).
0 = The oven will not restart a program that has been interrupted because of power cut.
1 = The oven will restart a program that has been interrupted because of power cut.
Shift by pressing key (3).
U4: Selecting Pre-Set/Current Temperature
Pre-set/current temperature
1 or 0 is shown in the time display (1).
0 = Pre-set temperature (standard)
1 = Current temperature during operation
Shift by pressing (3).
U5: Selecting Phase Sequence Test And Reversing
Phase sequence test
Phase sequence test is usually always active.
This alarm can be deactivated in the case of installation for demonstration purposes in order to avoid
error code 15.
The temperature display shows either ON or OFF. ON and OFF are selected by pressing (6).
VS Controller System Settings
Set-Up Mode Settings
U1 Automatic restart (1)
U2 Not Used
U3 Not Used
U4 Pre-set/current temperature (1)
U5 Phase Sequence Test (OFF)