Service manual
Combi-Oven Installation
11
Start-Up Window
When the computer is switched on, it checks all control lamps and segments to make sure that they work.
Figures appear in the displays:
• The time display shows how U1 is set.
• The temperature display shows the current EPROM version.
• The display for core temperature shows whether the computer includes CombiClean (0 = without
CC, 1= with CC).
Accessing the Set-Up Mode
Select the set-up mode by pressing key (4) and key (2) simultaneously for 5 sec. U1 appears in the time
display. Shift to the next setting (max. U5) by pressing key (2). The set-up mode can be
interrupted/closed any time by pressing key (18).
U1: Selecting Automatic Restart, Oven Model And Voltage
Automatic restart
1 or 0 is shown in the time display (1).
0 = The oven will not restart a program that has been interrupted because of power cut.
1 = The oven will restart a program that has been interrupted because of power cut.
Shift by pressing key (3).
Oven model
A digit between 1 and 6 is shown in the program display (17).
1 = CM, 2 = CV, 3 = BM, 4 = ST, 5=S, 6=VS
Shift by pressing (17).
Voltage
1 or 2 is shown in the core temperature display (8).
1 = Voltage with 0
2 = Voltage without 0
Shift by pressing the core temperature key (9).
U2: Selecting Interior Light
When the program display (17) shows 5, the interior light is automatically switched off after 5 min.
When the program display (17) shows 0, the interior light will shine continuously.
When the program display (17) shows 6, the interior light is automatically switched off after 5 min. In
addition, the light in the oven door is switched off after 3 sec. when the door is opened.
When the program display (17) shows 1, the oven light will shine continuously. In addition, the light in the
oven door is turned off after 3 sec. when the door is opened.
Settings 1 and 6 are very useful on ovens with oven light in the door in order to avoid blinding while the
door is open.
Shift by pressing (17).