Service manual
Combi-Oven Installation
9
Setting System Options for CVC Controller
System options are set through Engineering menus. To access these menus press and hold the F1 key
while pressing the START/STOP key. A list of menu commands will appear in the display. To see
additional menu commands press F1. To return to the main display, press the ENTER/STEP key. To
select a command, access it’s menu then press the numeric key associated with the command. Upon
selecting a command, its options will be displayed. To select/activate and navigate the command options
use the keys specified on the display. Return to the Engineering menu by pressing F1. The following table
lists the command options that need to be set to enable proper operation of the BKI Combi.
CVC Controller System Settings
Menu Command Option Settings
1 = TEST FUNCTION
2 = ENCODE OVEN TYPE
3 = SELECT LANGUAGE
Only used to troubleshoot oven.
2 = Autorestart
4 = GB
2 = Adjust PT100 sensors
3 = Set Restart Time
The values are factory set by the manufacturer.
Consult manufacturer before adjusting.
Leave as is
1 = Oven Light ON/OFF
2 = Phase Test
3 = Transfer all menus
1 = Oven light 5min.
OFF
Enter = OK
1 = Setup
2 = Motor Alarm
3 = Cleaning mode
Oven type (2 = CVC)
Temperature mode (2 = Fahrenheit)
Keyboard (2 = BKI)
Special mode (1 = Normal)
Fan (1= Single direction)
Language (4 = GB)
OFF
1 = Normal 2 step
1 = Access Code
2 = Warm up in step 1
3 = Condensation ON/OFF
4 = Show empty tray
OFF
Normal 6 step
Leave as is
Leave as is